AU-3P4/5/6/8/10/12K4G-HE

High Voltage | Three Phase

Hybrid Inverter

98.2

Max.Efficiency

15

PV Input Current

10

UPS Switch

110

Unbalanced Load

Product FEATURES

IP65 protection degree

Compact and elegant design
with integrated diecasting
technology

Long-term efficient operation
with advanced heat dissipation
design

Convenient installation and O&M
with horizontal design and
quickplug terminals

Easy data check via both
OLED display and App

Easy Wifi configuration via
App

Ideal for residential application
with low operating noise

Rich Reports

Compatibility

Management

DETAILED PARAMETERS
Model AU-3P4K4G-HE AU-3P5K4G-HE AU-3P6K4G-HE AU-3P8K4G-HE AU-3P10K4G-HE AU-3P12K4G-HE
PV Input  
Max.Input Power(KW) 6.0 7.5 9.0 12.0 15.0 18.0
Start-up Voltage (V) 135 135 135 135 135 135
Max.DC Input Voltage (V)* 1000 1000 1000 1000 1000 1000
Rated DC input voltage (V) 620 620 620 620 620 620
MPPT voltage range (V) 120-950 120-950 120-950 120-950 120-950 120-950
No. of MPP trackers 2  2  2  2  2 2
No. of DC inputs per MPPT 1/1 1/1 1/1 1/1 1/1 1/1
Max. input current (A) 15/15 15/15 15/15 15/15 15/15 15/15
Max. short-circuit current (A) 20/20 20/20 20/20 20/20 20/20 20/20
Battery Side  
Battery type Lithium Battery (with BMS)
Battery voltage type (V) 135-750
Maximum charging/discharge current (A) 25/25
Grid Side
Rated Output Power (kW) 4.0 5.0 6.0 8.0 10.0 12.0
Max. Output Apparent Power (kVA) 4.4 5.5 6.6 8.8 11.0 13.2
Max. Intput Apparent Power (kVA)** 8.0 10.0 12.0 16.0 16.5 16.5
Max. Charging Power of Battery (KVA) 4.0 5.0 6.0 8.0 10.0 12.0
Rated AC Voltage (V) 3LN/PE;220/380V;230/400V,240/415V  
Rated AC Frequency (Hz) 50/60 50/60 50/60 50/60 50/60 50/60
Max. Output Current (A) 6.7 8.3 10.0 13.3 16.5 20.0
Power Factor 0.8 leading ...0.8 lagging
Max. Total Harmonic Distortion <3% @Rated output power
DCI <0.5%ln <0.5%In <0.5%In <0.5%In <0.5%In <0.5%ln
Back-up Side  
Rated Output Power (kW) 4.0 5.0 6.0 8.0 10.0 12.0
Max. Output Apparent Power (KVA) 4.4 5.5 6.6 8.8 11.0 13.2
Max. Output Current (A) 6.7 8.3 10.0 13.3 16.5 20.0
UPS Switching Time <10ms <10ms <10ms <10ms <10ms <10ms
Rated Output Voltage (V) 3N/PE;220/380V,230/400V:240/415V
Rated Output Frequency (Hz) 50/60 50/60 50/60 50/60 50/60 50/60
Peak Out Apparent Power (kVA)*** 8,60s 10,60s 12,60s 16,60s 20,60s 20,60s
Voltage Harmonic Distortion <3%@Liner load  
Efficiency
Max. Efficiency 98.1% 98.1% 98.1% 98.2% 98.2% 98.2%
European Efficiency 98.3% 98.3% 98.3% 97.4% 97.4% 97.4%
Compliance IEC/EN 62109,IEC/EN 61000,EN50549-1,TOP Generator Type A,VDE-AR-N-4105
Protection
DC Reverse Polarity Protection Integrated
Battery Input Reverse Connection Protection Integrated
Insulation Resistance Protection Integrated
Surge Protection Integrated
Over-temperature Protection Integrated
Residual Current Protection Integrated
Islanding Protection Integrated
AC Over-voltage Protection Integrated
Overload Protection Integrated
AC Short-circuit Protection Integrated
General Data
Over Voltage Category PV: ll; Main:Ⅲ
Dimensions (W×H×D mm) 534×418×210
Weight (KG) 26
Protection Degree IP65
Standby Self-consumption (W) <15
Topology Transformerless
Operating Temperature Range(C) -30~60
Relative Humidity (%) 0~100
Operating Altitude (m) 3000(>3000m derating)
Cooling Natural Convection
Noise Level(dB) <25
Display OLED & LED
Communication

CAN, RS485, WiFi/LAN (Optional)

 

* Max. operating DC voltage is 950V, max. withstanding DC voltage is 1000V

** Max. apparent power from the grid means the maximun power from the utility grid used to satisfy the backup and charge the battery

*** The output power will exceed the rated value only when the power in the PV array is sufficient, and the dyration of the overload is related to the overload power

You are welcome to leave a message to contact us