AU-1P3/3.6/4.2/5/6/8K4G-HE

High Voltage | Single Phase

Hybrid Inverter

97.6

Max.Efficiency

15

PV Input Current

10

UPS Switch

110

Unbalanced Load

Product FEATURES

IP65 protection degree

Compact and elegant design
with integrated diecasting
technology

Long-term efficient operation
with advanced heat dissipation
design

Intelligent energy
management with built-in
EMS

Convenient installation and O&M
with horizontal design and
quickplug terminals

Easy data check via both
OLED display and App

AUSTA self-developed monitoring
App

Ideal for residential application
with low operating noise

Rich Reports

Compatibility

Management

DETAILED PARAMETERS
Model AU-1P3K4G-HE AU-1P3.6K4G-HE AU-1P4.2K4G-HE AU-1P5K4G-HE AU-1P6K4G-HE AU-1P8K4G-HE
Battery Parameters
Battery Type Lithium Battery (with BMS)
Battery voltage Range (V) 85-465
Max. Charge/Discharge Current (A) 30/30
Input DC (PV side)
Max. Input Power (kW) 4.8 5.76 6.72 8.00 9.60 12.8
Start-up Voltage (V) 80 80 80 80 80 80
Max. DC Input Voltage (V) 600 600 600 600 600 600
Rated DC Input Voltage (V) 360 360 360 360 360 360
MPPT Voltage Range (V) 100-550 100-550 100-550 100-550 100-550 100-550
No. of MPPT Trackers 1 1 2 2 2 2
No. of DC Inputs per MPPT 1 1 1/1 1/1 1/1 1/1
Max. Input Current (A) 15 15 15/15 15/15 15/15 15/15
Max. Short-circuit Current (A) 20 20 20/20 20/20 20/20 20/20
Output / Input AC (Grid side)
Rated Output Power (kW) 3.00 3.60 4.20 5.00 6.00 8.00
Max. Output Apparent Power (kVA) 3.30 3.96 4.60 5.50 6.60 8.00
Max. Intput Apparent Power (kVA) 6.00 7.20 8.40 10.00 12.00 12.00
Max. Charging Power of Battery (KVA) 3.00 3.60 4.20 5.00 6.00 8.00
Rated AC Voltage (V) L/N/PE; 220/230/240V
Rated AC Frequency (Hz) 50/60 50/60 50/60 50/60 50/60 50/60
Max. Output Current (A) 15.00 18.00 21.00 25.00 28.70 36.30
Power Factor 0.8 leading ...0.8 lagging
Max. Total Harmonic Distortion <3% @Rated output power
DCI <0.5%In <0.5%In <0.5%In <0.5%In <0.5%In <0.5%In
Output AC(Emergency Power Supply)
Rated Output Power (kW) 3.00 3.60 4.20 5.00 6.00 8.00
Max. Output Apparent Power (KVA) 3.30 3.96 4.60 5.50 6.60 8.00
Max. Output Current (A) 15.00 18.00 21.00 25.00 28.70 36.30
UPS Switching Time <10ms <10ms <10ms <10ms <10ms <10ms
Rated Output Voltage (V) L/N/PE; 220/230/240V
Rated Output Frequency (Hz) 50/60 50/60 50/60 50/60 50/60 50/60
Peak Output Apparent Power (KVA) 3.9,60s 4.7,60s 5.5,60s 6.5,60s 7.8,60s 10,60s
Voltage Harmonic Distortion <3%@Liner load
Efficiency
Max. efficiency of solar inverter 97.6% 97.6% 97.6% 97.6% 97.6% 97.6%
European efficiency of solar inverter 97.0% 97.0% 97.0% 97.0% 97.0% 97.0%
Protection
DC Reverse Polarity Protection Integrated
Battery Input Reverse Connection Protection Integrated
Insulation Resistance Protection Integrated
Surge Protection Integrated
Over-temperature Protection Integrated
Residual Current Protection Integrated
Islanding Protection Integrated
AC Over-voltage Protection Integrated
Overload Protection Integrated
AC Short-circuit Protection Integrated
General Data
Over Voltage Category PV: ll; Main:Ⅲ
Dimensions (W×H×D mm) 534×418×210
Weight (KG) 27.0
Protection Degree IP65
Standby Self-consumption (W) <15
Topology Transformerless
Operating Temperature Range(C) -30~60
Relative Humidity (%) 0~100
Operating Altitude (m) 3000(>3000m derating)
Cooling Natural Convection
Noise Level(dB) <25
Display OLED & LED
Communication CAN, RS485, WiFi/LAN (Optional)
Certifications & Standards
EMC EN 50549-1, TOR Generator Type A
Safety standards IEC/EN 62109, IEC /EN 61000
Grid standards VDE-AR-N-4105