TS4-A-F

Optimizer

99.9

Efficiency

700

Maximum Wattage

90

Maximum Input Voltage

25

Warranty

Product FEATURES

Now rated for 20A Imp/ 25A Isc to better accommodate bifacial and high current modules

Snap to standard PV module frame or remove clips for rack mounting

 

Rapid shutdown signaling over PV conductors

 

PV array enters rapid shutdown in the event of AC grid loss

 

Tested and UL certified with hundreds of top inverter models

DETAILED PARAMETERS
Quick Specs
TS4-A-F
Dimensions (W x H x D) 138.4 x 139.7 x 22.9mm (5.9 x 5.5 x 0.9in)
Weight 490g (1.1lbs)
Max Current (Imp/Isc)* 15A 20A/25A
Max Wattage 700W

 

*Use local codes/requirements to calculate maximum current.

 

Electrical Data 15A 25A
Maximum input voltage 90V 80V
Operating voltage range¹ 16 - 90V 16 - 80V
Maximum input current (Imp) N/A 25A
Maximum wattage 15A 20A
Max Wattage 700W 700W

 

¹Maximum output voltage of the TS4 is dependent on the PV module voltage. Refer to PV modules nameplate.

 

Connections
Module Conductor lengths 0.12m, 0.62m, options
available²
0.62m, options
available²
String Conductor lengths 1.2m, options available²
Connectors MC4, EVO2, options available²

 

²Contact sales for additional connector and conductor length options. MOQ may apply.

 

General Data
Operating temperature range UL: -30°C to +75°C(-22°F to +167°F)
IEC: -40°C to +85°C(-40°F to +185°F)
UL/IEC:-40°C to +80°C(-40°F to +176°F)
Storage temperature range -40°C to +85°C(-40°F to +185°F) -40°C to +85°C(-40°F to +185°F)
Recommended fuse rating 20A 30A
Outdoor rating IP68, NEMA 3R IP68
Maximum altitude 2000m 3000m
Efficiency 99.6% 99.9%
Communication PLC
Rapid Shutdown UL Listed(NEC 2017 & 2020 690.12) Yes
Rapid Shutdown Time Limit 30 secs or less³
Conductor AWG Range 10-12 AWG
PVRSE Controlled Conductors ≤30 Vdc, ≤240VA, ≤8A³
Warranty 25 years
Certifications UL1741, PVRSS, CSA22.2, IEC 62109
PVRSS certified inverters For a list of all PVRSS certified inverters, please see: www.tigoenergy.com/ul-pvrss

 

³Limits are based on NEC 690.12 rapid shutdown requirements.

 

 