High Voltage | Three Phase
Hybrid Inverter
IP65 for indoor and outdoor installation
Compact and elegant design
with integrated diecasting
technology
Long-term efficient operation
with advanced heat dissipation
design
Intelligent energy
management with built-in
EMS
Convenient installation and O&M
with horizontal design and
quickplug terminals
Easy data check via both
OLED display and App
AUSTA self-developed monitoring
App
Ideal for residential application
with low operating noise
Rich Reports
Compatibility
Management
Model | AU-3P25K4G-HE | AU-3P30K4G-HE | AU-3P36K4G-HE | AU-3P40K4G-HE | AU-3P50K4G-HE |
PV Input | |||||
Recommended Max. input power AU-3P50K4G-HE (kW) | 37.5 | 45.0 | 54.0 | 60.0 | 75.0 |
Start-up voltage (V) | 135 | 135 | 135 | 135 | 135 |
Max. DC input voltage* (V) | 1000* | 1000* | 1000* | 1000* | 1000* |
Rated DC input voltage (V) | 620 | 620 | 620 | 620 | 620 |
MPPT voltage range* (V) | 200-850* | 200-850* | 200-850* | 200-850* | 200-850* |
No. of MPP trackers | 4 | 4 | 4 | 4 | 4 |
No. of DC inputs per MPPT | 2 | 2 | 2 | 2 | 2 |
Max. input current (A) | 30×4 | 30×4 | 30×4 | 30×4 | 30×4 |
Max. short-circuit current (A) | 40×4 | 40×4 | 40×4 | 40×4 | 40×4 |
Battery Side | |||||
Battery type | Lithium Battery (with BMS) | ||||
Battery voltage type (V) | 135-750 | ||||
Maximum charging/discharge current (A) | 100/100 | ||||
Grid Side | |||||
Rated Output Power (kW) | 25.0 | 30.0 | 36.0 | 40.0 | 50.0 |
Max. Output Apparent Power (kVA) | 27.5 | 33.01) | 39.6 | 44.0 | 55.0 |
Max. Intput Apparent Power (kVA) | 30.0 | 36.0 | 43.5 | 48.0 | 60.0 |
Max. Charging Power of Battery (KVA) | 25.0 | 30.0 | 36.0 | 40.0 | 50.0 |
Rated AC Voltage (V) | 3L/N/PE; 220/380V;230/400V;240/415V | ||||
Rated AC Frequency (Hz) | 50/60 | 50/60 | 50/60 | 50/60 | 50/60 |
Max. Output Current (A) | 42.0 | 50.02) | 60.0 | 66.0 | 83.0 |
Power Factor | 0.8 leading ...0.8 lagging | ||||
Max. Total Harmonic Distortion | <3% @Rated output power | ||||
DCI | <0.5%In | <0.5%In | <0.5%In | <0.5%In | <0.5%In |
Back-up Side | |||||
Rated Output Power (kW) | 25.0 | 30.0 | 36.0 | 40.0 | 50.0 |
Max. Output Apparent Power (KVA) | 27.5 | 33.0 | 39.6 | 44.0 | 55.0 |
Max. Output Current (A) | 42.0 | 50.0 | 60.0 | 66.0 | 83.0 |
UPS Switching Time | <20ms | <20ms | <20ms | <20ms | <20ms |
Rated Output Voltage (V) | L/N/PE; 220/230/240V | ||||
Rated Output Frequency (Hz) | 50/60 | 50/60 | 50/60 | 50/60 | 50/60 |
Voltage Harmonic Distortion | <3%@Liner load | ||||
Efficiency | |||||
Max. efficiency of solar inverter | 98.8% | 98.8% | 98.8% | 98.8% | 98.8% |
European efficiency of solar inverter | 98.3% | 98.3% | 98.3% | 98.3% | 98.3% |
Protection | |||||
DC Reverse Polarity Protection | Integrated | ||||
Battery Input Reverse Connection Protection | Integrated | ||||
Insulation Resistance Protection | Integrated | ||||
Surge Protection | Integrated | ||||
Over-temperature Protection | Integrated | ||||
Residual Current Protection | Integrated | ||||
Islanding Protection | Integrated | ||||
AC Over-voltage Protection | Integrated | ||||
Overload Protection | Integrated | ||||
AC Short-circuit Protection | Integrated | ||||
General Data | |||||
Over Voltage Category | PV: ll; Main:Ⅲ | ||||
Dimensions (W×H×D mm) | 800×620×300 | ||||
Weight (KG) | 72.0 | ||||
Protection Degree | IP65 | ||||
Standby Self-consumption (W) | <15 | ||||
Topology | Transformerless | ||||
Operating Temperature Range(C) | -30~60 | ||||
Relative Humidity (%) | 0~100 | ||||
Operating Altitude (m) | 3000(>3000m derating) | ||||
Cooling | Smart fan | ||||
Noise Level(dB) | <50 | ||||
Display | OLED & LED | ||||
Communication | CAN, RS485, WiFi/LAN (Optional) |
*PV Max.Input voltage is 850V,otherwise inverter will be waiting;
**Max apparent power from the grid means the maximum power imported from the utility grid used to satisfy the backup loads and charge the battery;
1)AS4777.2,VDE-AR-N4105:30.0KVA:2)AS4777.2,VDE-AR-N4105:43.5A