AU-3P25/30/36/40/50K4G-HE

High Voltage | Three Phase

Hybrid Inverter

98.8

Max.Efficiency

30

PV Input Current

20

UPS Switch

100

Unbalanced Output

Product FEATURES

IP65 for indoor and outdoor installation

Compact and elegant design
with integrated diecasting
technology

Long-term efficient operation
with advanced heat dissipation
design

Intelligent energy
management with built-in
EMS

Convenient installation and O&M
with horizontal design and
quickplug terminals

Easy data check via both
OLED display and App

AUSTA self-developed monitoring
App

Ideal for residential application
with low operating noise

Rich Reports

Compatibility

Management

DETAILED PARAMETERS
Model AU-3P25K4G-HE AU-3P30K4G-HE AU-3P36K4G-HE AU-3P40K4G-HE AU-3P50K4G-HE
PV Input
Recommended Max. input power AU-3P50K4G-HE (kW) 37.5 45.0 54.0 60.0 75.0
Start-up voltage (V) 135 135 135 135 135
Max. DC input voltage* (V) 1000* 1000* 1000* 1000* 1000*
Rated DC input voltage (V) 620 620 620 620 620
MPPT voltage range* (V) 200-850* 200-850* 200-850* 200-850* 200-850*
No. of MPP trackers 4  4  4  4  4
No. of DC inputs per MPPT 2 2 2 2 2
Max. input current (A) 30×4 30×4 30×4 30×4 30×4
Max. short-circuit current (A) 40×4 40×4 40×4 40×4 40×4
Battery Side
Battery type Lithium Battery (with BMS)
Battery voltage type (V) 135-750
Maximum charging/discharge current (A) 100/100
Grid Side
Rated Output Power (kW) 25.0 30.0 36.0 40.0 50.0
Max. Output Apparent Power (kVA) 27.5 33.01) 39.6 44.0 55.0
Max. Intput Apparent Power (kVA) 30.0 36.0 43.5 48.0 60.0
Max. Charging Power of Battery (KVA) 25.0 30.0 36.0 40.0 50.0
Rated AC Voltage (V) 3L/N/PE; 220/380V;230/400V;240/415V
Rated AC Frequency (Hz) 50/60 50/60 50/60 50/60 50/60
Max. Output Current (A) 42.0 50.02) 60.0 66.0 83.0
Power Factor 0.8 leading ...0.8 lagging
Max. Total Harmonic Distortion <3% @Rated output power
DCI <0.5%In <0.5%In <0.5%In <0.5%In <0.5%In
Back-up Side
Rated Output Power (kW) 25.0 30.0 36.0 40.0 50.0
Max. Output Apparent Power (KVA) 27.5 33.0 39.6 44.0 55.0
Max. Output Current (A) 42.0 50.0 60.0 66.0 83.0
UPS Switching Time <20ms <20ms <20ms <20ms <20ms
Rated Output Voltage (V) L/N/PE; 220/230/240V
Rated Output Frequency (Hz) 50/60 50/60 50/60 50/60 50/60
Voltage Harmonic Distortion <3%@Liner load
Efficiency
Max. efficiency of solar inverter 98.8% 98.8% 98.8% 98.8% 98.8%
European efficiency of solar inverter 98.3% 98.3% 98.3% 98.3% 98.3%
Protection
DC Reverse Polarity Protection Integrated
Battery Input Reverse Connection Protection Integrated
Insulation Resistance Protection Integrated
Surge Protection Integrated
Over-temperature Protection Integrated
Residual Current Protection Integrated
Islanding Protection Integrated
AC Over-voltage Protection Integrated
Overload Protection Integrated
AC Short-circuit Protection Integrated
General Data
Over Voltage Category PV: ll; Main:Ⅲ
Dimensions (W×H×D mm) 800×620×300
Weight (KG) 72.0
Protection Degree IP65
Standby Self-consumption (W) <15
Topology Transformerless
Operating Temperature Range(C) -30~60
Relative Humidity (%) 0~100
Operating Altitude (m) 3000(>3000m derating)
Cooling Smart fan
Noise Level(dB) <50
Display OLED & LED
Communication CAN, RS485, WiFi/LAN (Optional)

 

*PV Max.Input voltage is 850V,otherwise inverter will be waiting;

**Max apparent power from the grid means the maximum power imported from the utility grid used to satisfy the backup loads and charge the battery;

1)AS4777.2,VDE-AR-N4105:30.0KVA:2)AS4777.2,VDE-AR-N4105:43.5A

You are welcome to leave a message to contact us

+86